某電力集團300MW机组电除尘器改造

● 配置2台双室四电场电除尘器,设计处理工况烟气量1132325m3/h;
● 电除尘器供电装置为16台单相工频电源1.2A/72KV;
● 改造前电除尘器出口粉尘排放浓度80-100mg/Nm3。

本體檢修主要內容:

● 振打系统修复;
● 加热系统修复;
● 电场内部进行清灰、更换受损的阴极线,调整极距等检修工作;

電氣改造內容:

● 将16台工频电源控制柜改造为智能变频脉冲电源控制柜;
● 整流变压器、隔离开关柜和供电电缆利旧;
● 低压系统进行更换并优化控制程序;
● 新增上位机系统,实现对高低压电源参数监控显示。

● 15天内完成了电除尘器检修和电源改造工作;
● 升级改造后电除尘器出口粉尘排放浓度 <30mg/Nm3。